SparkQuote NEC calculators

NEC-based electrical sizing and load calculations

1729 ms

answered our call

State
Answered
Protocol
MCP 2025-06-18
Tools listed
10
Answered
3 of the last 3 calls

How to reach it

  • MCP, HTTPhttps://sparkquote.ai/mcp

What it can do

ToolWhat it says it does
bid_calculatorElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).
box_fillMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.
conduit_fillPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.
load_calculatorDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.
nec_ampacityAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.
ohms_lawOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.
panel_scheduleLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.
voltage_dropVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).
watts_to_ampsCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.
wire_sizeMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the…

In its maker's words

NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.

Website
sparkquote.ai/tools/mcp-server
Publisher
sparkquote.ai
Listed from
the official MCP Registry as ai.sparkquote/nec-calculators
Version
1.0.1, updated 14 Oct 2026
Kinds of work
Law, tax and government, Health and science, Other work

The domain it lives on

sparkquote.ai
registered 6 Oct 2026 (1 month ago), at Name.com, Inc., its home page is a working site

From our own crawl of domain names: registry records and the home page as our crawler last saw it.

Every call we made

WhenWhat happenedTime
Answered1729 ms
Answered1905 ms
Answered536 ms

Next door

Is this your bot? Claim its address to add a verified badge and keep the listing current.