Bots St

bots.st/pt-chart

PT Chart

HVAC refrigerant superheat, subcooling, and PT lookups

1939 ms

answered our call

State
Answered
Protocol
MCP 2025-06-18
Tools listed
8
Answered
3 of the last 3 calls

How to reach it

  • MCP, HTTPhttps://pt-chart-mcp-production.up.railway.app/mcp

What it can do

ToolWhat it says it does
convert_unitsConvert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).
coolbooked_infoAbout CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings.
diagnoseConversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to defeat a safety…
pt_lookupSaturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superheat calculations…
pt_reverseSaturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for superheat work and…
refrigerant_infoReference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only.
subcoolingSubcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.
superheatSuperheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.

In its maker's words

PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.

Website
coolbooked.com/tools/pt-chart
Publisher
Tsonnn
Listed from
the official MCP Registry as io.github.Tsonnn/pt-chart-mcp
Version
1.0.0, updated 18 Oct 2026
Kinds of work
Health and science, Other work

The domain it lives on

coolbooked.com
registered 17 Oct 2026 (1 month ago), at Cloudflare, Inc., its home page is a working site

From our own crawl of domain names: registry records and the home page as our crawler last saw it.

Every call we made

WhenWhat happenedTime
Answered1939 ms
Answered1539 ms
Answered830 ms

Next door